The Cyber Essentials v3.3 Firewalls domain has 8 controls. This page lists every one, in plain language, with what it asks of you and the kind of evidence that actually satisfies it. Cyber Essentials v3.3 (UK).
By Aneis Samaan, founder of CyberSentien · Last updated November 2026 · Sourced from the Cyber Essentials v3.3 control set.
These 8 controls are the Firewalls slice of Cyber Essentials v3.3. Read them as the questions an assessor will ask, and the artefacts you will be asked to produce for each. Below every control we keep the language of the source; the value we add is turning each into an evidence question you can answer honestly.
| Control | What it requires |
|---|---|
CE-FW-01 | CE FW-01 — Alternatively, if your organisation doesn't control the network to which a device… Alternatively, if your organisation doesn't control the network to which a device connects, you must configure a software firewall on the device. |
CE-FW-02 | CE FW-02 — You must protect every device in scope with a correctly configured firewall (or… You must protect every device in scope with a correctly configured firewall (or network device with firewall functionality). |
CE-FW-03 | CE FW-03 — Change default administrative passwords to a strong and unique password (see… For all firewalls (or network devices with firewall functionality), your organisation must: change default administrative passwords to a strong and unique password (see password-based authentication) – or disable remote administrative access entirely |
CE-FW-04 | CE FW-04 — Prevent access to the administrative interface (used to manage firewall… For all firewalls (or network devices with firewall functionality), your organisation must: prevent access to the administrative interface (used to manage firewall configuration) from the internet, unless there is a clear and documented business need, and the interface is protected by one of the following controls: multi-factor authentication (see MFA details below) an IP allow list that limits access to a small range of trusted addresses combined with a properly managed password authentication approach |
CE-FW-05 | CE FW-05 — Block unauthenticated inbound connections by default For all firewalls (or network devices with firewall functionality), your organisation must: block unauthenticated inbound connections by default |
CE-FW-06 | CE FW-06 — Ensure inbound firewall rules are approved and documented by an authorised person… For all firewalls (or network devices with firewall functionality), your organisation must: ensure inbound firewall rules are approved and documented by an authorised person, and include the business need in the documentation |
CE-FW-07 | CE FW-07 — Remove or disable unnecessary firewall rules, when they are no longer needed For all firewalls (or network devices with firewall functionality), your organisation must: remove or disable unnecessary firewall rules, when they are no longer needed |
CE-FW-08 | CE FW-08 — Make sure you use a software firewall on devices which are used on untrusted… Make sure you use a software firewall on devices which are used on untrusted networks, such as public wifi hotspots. |
The failure mode is the same in every framework: a control marked ‘compliant’ with nothing behind it. An assertion is not evidence. For each control above, the honest test is whether you can point to a dated, specific artefact — a configuration export, a log extract, a signed policy, a register entry — not a claim that you ‘do that’. That is exactly what CyberSentien enforces: a control with no evidence reads manual assessment required, never a fabricated pass. How the engine assesses →
You do not answer to one framework in isolation. The same body of evidence maps across everything you are accountable to — which is the whole point of assessing once against real evidence and reporting everywhere. Related on this site:
There are 8 controls in this domain of Cyber Essentials v3.3. They are all listed above with what each requires.
Evidence is specific and dated: configuration exports, logs, signed policies, register entries and test results tied to the control, not a written assertion that the control exists. CyberSentien refuses to mark a control compliant without that lineage.
Yes. Cyber Essentials v3.3 is one of the frameworks live on the CyberSentien engine, assessed against your real evidence with honest coverage and tamper-evident report lineage.
Every capability referenced on this page is live on the CyberSentien engine — see it on the always-live gated demo. Nothing on this page is legal advice.