The Cyber Essentials v3.3 User access control domain has 17 controls. This page lists every one, in plain language, with what it asks of you and the kind of evidence that actually satisfies it. Cyber Essentials v3.3 (UK).
By Aneis Samaan, founder of CyberSentien · Last updated November 2026 · Sourced from the Cyber Essentials v3.3 control set.
These 17 controls are the User access control slice of Cyber Essentials v3.3. Read them as the questions an assessor will ask, and the artefacts you will be asked to produce for each. Below every control we keep the language of the source; the value we add is turning each into an evidence question you can answer honestly.
| Control | What it requires |
|---|---|
CE-UAC-01 | CE UAC-01 — Your organisation must be in control of your user accounts and the access… Your organisation must be in control of your user accounts and the access privileges that allow access to your organisational data and services. |
CE-UAC-02 | CE UAC-02 — It’s important to note that this also includes third party accounts – for example… It’s important to note that this also includes third party accounts – for example, accounts used by your support services. |
CE-UAC-03 | CE UAC-03 — You also need to understand how user accounts authenticate and manage the… You also need to understand how user accounts authenticate and manage the authentication accordingly. |
CE-UAC-04 | CE UAC-04 — Have in place a process to create and approve user accounts This means your organisation must: have in place a process to create and approve user accounts |
CE-UAC-05 | CE UAC-05 — Authenticate users with unique credentials before granting access to applications… This means your organisation must: authenticate users with unique credentials before granting access to applications or devices |
CE-UAC-06 | CE UAC-06 — Remove or disable user accounts when they’re no longer required (for example, when… This means your organisation must: remove or disable user accounts when they’re no longer required (for example, when a user leaves the organisation or after a defined period of account inactivity) |
CE-UAC-07 | CE UAC-07 — Implement MFA, where available – authentication to cloud services must always use… This means your organisation must: implement MFA, where available – authentication to cloud services must always use MFA |
CE-UAC-08 | CE UAC-08 — Use separate accounts to perform administrative activities only (no emailing, web… This means your organisation must: use separate accounts to perform administrative activities only (no emailing, web browsing or other standard user activities that may expose administrative privileges to avoidable risks) |
CE-UAC-09 | CE UAC-09 — Remove or disable special access privileges when no longer required (when a member… This means your organisation must: remove or disable special access privileges when no longer required (when a member of staff changes role, for example) |
CE-UAC-10 | CE UAC-10 — As well as providing an extra layer of security for passwords that aren’t protected… As well as providing an extra layer of security for passwords that aren’t protected by the other technical controls, you should always use multi-factor authentication to give administrative accounts extra security, and accounts that are accessible from the internet. |
CE-UAC-11 | CE UAC-11 — The password element of the multi-factor authentication approach must have a… The password element of the multi-factor authentication approach must have a password length of at least 8 characters, with no maximum length restrictions. |
CE-UAC-12 | CE UAC-12 — Additional factors should be chosen so that they are usable and accessible. Additional factors should be chosen so that they are usable and accessible. |
CE-UAC-13 | CE UAC-13 — All user accounts require the user to authenticate. All user accounts require the user to authenticate. |
CE-UAC-14 | CE UAC-14 — Passwords are protected against brute-force password guessing by implementing at… Where authentication is carried out using a password, you should put in place the following protective measures: Passwords are protected against brute-force password guessing by implementing at least one of: multi-factor authentication (see above) ‘throttling' the rate of attempts, so that the length of time the user must wait between attempts increases with each unsuccessful attempt. You should allow no more than 10 guesses in 5 minutes locking devices after no more than 10 unsuccessful attempts |
CE-UAC-15 | CE UAC-15 — Use technical controls to manage the quality of passwords. This will include one of… Where authentication is carried out using a password, you should put in place the following protective measures: Use technical controls to manage the quality of passwords. This will include one of the following: Using multi-factor authentication (see above) A minimum password length of at least 12 characters, with no maximum length restrictions A minimum password length of at least 8 characters, with no maximum length restrictions and use automatic blocking of common passwords using a deny list |
CE-UAC-16 | CE UAC-16 — Support users to choose unique passwords for their work accounts by: Where authentication is carried out using a password, you should put in place the following protective measures: Support users to choose unique passwords for their work accounts by: educating people about avoiding common passwords, such as a pet's name, common keyboard patterns or passwords they have used elsewhere. This could include teaching people to use the password generator feature built into some password managers encouraging people to choose longer passwords by promoting the use of multiple words (a minimum of three) to create a password (such as the NCSC’s guidance on using three random words) providing usable secure storage for passwords (for example a password manager or secure locked cabinet) with clear information about how and when it can be used not enforcing regular password expiry not enforcing password complexity requirements |
CE-UAC-17 | CE UAC-17 — You should also make sure there is an established process in place to change… You should also make sure there is an established process in place to change passwords promptly if you know or suspect a password or account has been compromised. |
The failure mode is the same in every framework: a control marked ‘compliant’ with nothing behind it. An assertion is not evidence. For each control above, the honest test is whether you can point to a dated, specific artefact — a configuration export, a log extract, a signed policy, a register entry — not a claim that you ‘do that’. That is exactly what CyberSentien enforces: a control with no evidence reads manual assessment required, never a fabricated pass. How the engine assesses →
You do not answer to one framework in isolation. The same body of evidence maps across everything you are accountable to — which is the whole point of assessing once against real evidence and reporting everywhere. Related on this site:
There are 17 controls in this domain of Cyber Essentials v3.3. They are all listed above with what each requires.
Evidence is specific and dated: configuration exports, logs, signed policies, register entries and test results tied to the control, not a written assertion that the control exists. CyberSentien refuses to mark a control compliant without that lineage.
Yes. Cyber Essentials v3.3 is one of the frameworks live on the CyberSentien engine, assessed against your real evidence with honest coverage and tamper-evident report lineage.
Every capability referenced on this page is live on the CyberSentien engine — see it on the always-live gated demo. Nothing on this page is legal advice.