FedRAMP Physical and Environmental Protection controls (2026)

The FedRAMP Physical and Environmental Protection domain has 18 controls. This page lists every one, in plain language, with what it asks of you and the kind of evidence that actually satisfies it. The US FedRAMP baseline for cloud services used by federal agencies, drawn from NIST SP 800-53.

By Aneis Samaan, founder of CyberSentien · Last updated November 2026 · Sourced from the FedRAMP control set.

What the Physical and Environmental Protection domain covers

These 18 controls are the Physical and Environmental Protection slice of FedRAMP. Read them as the questions an assessor will ask, and the artefacts you will be asked to produce for each. Below every control we keep the language of the source; the value we add is turning each into an evidence question you can answer honestly.

The 18 controls in FedRAMP Physical and Environmental Protection

ControlWhat it requires
PE-1Policy and Procedures
Develop, document, and disseminate to [organization-defined personnel or roles]: [Selection (one or more): organization-level; mission/business process-level; system-level] physical and environmental protection policy that: Addresses purpose, scope, roles, responsibilities, management commitment, coordination among organizational entities, and compliance; and Is consistent with applicable laws, executive orders, directives, regulations, policies, standards, and guidelines; and Procedures to facilitate the implementation of the physical and environmental protection policy and the associated physical and environmental protection controls; Designate an [organization-defined official] to manage the development, documentation, and dissemination of the physical and environmental protection policy and procedures; and Review and update the current physical and environmental protection: Policy [organization-defined frequency] and following [organization-defined events]; and Procedures [organization-defined frequency] and following [organization-defined events].
PE-2Physical Access Authorizations
Develop, approve, and maintain a list of individuals with authorized access to the facility where the system resides; Issue authorization credentials for facility access; Review the access list detailing authorized facility access by individuals [organization-defined frequency]; and Remove individuals from the facility access list when access is no longer required.
PE-3Physical Access Control
Enforce physical access authorizations at [organization-defined entry and exit points] by: Verifying individual access authorizations before granting access to the facility; and Controlling ingress and egress to the facility using [Selection (one or more): [organization-defined systems or devices]; guards]; Maintain physical access audit logs for [organization-defined entry or exit points]; Control access to areas within the facility designated as publicly accessible by implementing the following controls: [organization-defined physical access controls]; Escort visitors and control visitor activity [organization-defined circumstances]; Secure keys, combinations, and other physical access devices; Inventory [organization-defined physical access devices] every [organization-defined frequency]; and Change combinations and keys [organization-defined frequency] and/or when keys are lost, combinations are compromised, or when individuals possessing the keys or combinations are transferred or terminated.
PE-4Access Control for Transmission
Control physical access to [organization-defined system distribution and transmission lines] within organizational facilities using [organization-defined security controls].
PE-5Access Control for Output Devices
Control physical access to output from [organization-defined output devices] to prevent unauthorized individuals from obtaining the output.
PE-6Monitoring Physical Access
Monitor physical access to the facility where the system resides to detect and respond to physical security incidents; Review physical access logs [organization-defined frequency] and upon occurrence of [organization-defined events]; and Coordinate results of reviews and investigations with the organizational incident response capability.
PE-6.1Intrusion Alarms and Surveillance Equipment
Monitor physical access to the facility where the system resides using physical intrusion alarms and surveillance equipment.
PE-8Visitor Access Records
Maintain visitor access records to the facility where the system resides for [organization-defined time period]; Review visitor access records [organization-defined frequency]; and Report anomalies in visitor access records to [organization-defined personnel].
PE-9Power Equipment and Cabling
Protect power equipment and power cabling for the system from damage and destruction.
PE-10Emergency Shutoff
Provide the capability of shutting off power to [organization-defined system or individual system components] in emergency situations; Place emergency shutoff switches or devices in [organization-defined location] to facilitate access for authorized personnel; and Protect emergency power shutoff capability from unauthorized activation.
PE-11Emergency Power
Provide an uninterruptible power supply to facilitate [Selection: an orderly shutdown of the system; transition of the system to long-term alternate power] in the event of a primary power source loss.
PE-12Emergency Lighting
Employ and maintain automatic emergency lighting for the system that activates in the event of a power outage or disruption and that covers emergency exits and evacuation routes within the facility.
PE-13Fire Protection
Employ and maintain fire detection and suppression systems that are supported by an independent energy source.
PE-13.1Detection Systems — Automatic Activation and Notification
Employ fire detection systems that activate automatically and notify [organization-defined personnel or roles] and [organization-defined emergency responders] in the event of a fire.
PE-14Environmental Controls
Maintain [Selection (one or more): temperature; humidity; pressure; radiation; [organization-defined environmental control] ] levels within the facility where the system resides at [organization-defined acceptable levels]; and Monitor environmental control levels [organization-defined frequency].
PE-15Water Damage Protection
Protect the system from damage resulting from water leakage by providing master shutoff or isolation valves that are accessible, working properly, and known to key personnel.
PE-16Delivery and Removal
Authorize and control [organization-defined types of system components] entering and exiting the facility; and Maintain records of the system components.
PE-17Alternate Work Site
Determine and document the [organization-defined alternate work sites] allowed for use by employees; Employ the following controls at alternate work sites: [organization-defined controls]; Assess the effectiveness of controls at alternate work sites; and Provide a means for employees to communicate with information security and privacy personnel in case of incidents.

The false-green trap in this domain

The failure mode is the same in every framework: a control marked ‘compliant’ with nothing behind it. An assertion is not evidence. For each control above, the honest test is whether you can point to a dated, specific artefact — a configuration export, a log extract, a signed policy, a register entry — not a claim that you ‘do that’. That is exactly what CyberSentien enforces: a control with no evidence reads manual assessment required, never a fabricated pass. How the engine assesses →

Assess once, report everywhere

You do not answer to one framework in isolation. The same body of evidence maps across everything you are accountable to — which is the whole point of assessing once against real evidence and reporting everywhere. Related on this site:

Frequently asked questions

How many controls are in the FedRAMP Physical and Environmental Protection domain?

There are 18 controls in this domain of FedRAMP. They are all listed above with what each requires.

What evidence satisfies these controls?

Evidence is specific and dated: configuration exports, logs, signed policies, register entries and test results tied to the control, not a written assertion that the control exists. CyberSentien refuses to mark a control compliant without that lineage.

Does CyberSentien assess FedRAMP?

Yes. FedRAMP is one of the frameworks live on the CyberSentien engine, assessed against your real evidence with honest coverage and tamper-evident report lineage.

Every capability referenced on this page is live on the CyberSentien engine — see it on the always-live gated demo. Nothing on this page is legal advice.