IEC 62443-3-2-aligned OT risk ZCR 3 — Partition into zones and conduits controls (2026)

The IEC 62443-3-2-aligned OT risk ZCR 3 — Partition into zones and conduits domain has 7 controls. This page lists every one, in plain language, with what it asks of you and the kind of evidence that actually satisfies it. CyberSentien's operational technology risk assessment, aligned to IEC 62443-3-2.

By Aneis Samaan, founder of CyberSentien · Last updated November 2026 · Sourced from the IEC 62443-3-2-aligned OT risk control set.

What the ZCR 3 — Partition into zones and conduits domain covers

These 7 controls are the ZCR 3 — Partition into zones and conduits slice of IEC 62443-3-2-aligned OT risk. Read them as the questions an assessor will ask, and the artefacts you will be asked to produce for each. Below every control we keep the language of the source; the value we add is turning each into an evidence question you can answer honestly.

The 7 controls in IEC 62443-3-2-aligned OT risk ZCR 3 — Partition into zones and conduits

ControlWhat it requires
ZCR 3.1Establish zones and conduits
The system under consideration is partitioned into zones and the conduits between them, and every asset is assigned to exactly one zone.
ZCR 3.2Separate business and control system assets
Business and enterprise assets are placed in zones separate from industrial automation and control system assets.
ZCR 3.3Separate safety related assets
Safety instrumented and other safety related assets are placed in their own zone, separated from non-safety assets.
ZCR 3.4Separate temporarily connected devices
Devices that connect temporarily, such as engineering laptops and maintenance equipment, are treated as their own zone rather than absorbed into the zone they attach to.
ZCR 3.5Separate wirelessly connected devices
Wirelessly connected devices are placed in a zone separate from wired control assets.
ZCR 3.6Separate devices reachable over external networks
Devices reachable from an external network are placed in a zone separate from devices that are not.
ZCR 3.7Document the zone and conduit model
The zone and conduit partitioning is documented, including each zone's assets, each conduit's endpoints, and the reason each boundary was drawn where it was.

The false-green trap in this domain

The failure mode is the same in every framework: a control marked ‘compliant’ with nothing behind it. An assertion is not evidence. For each control above, the honest test is whether you can point to a dated, specific artefact — a configuration export, a log extract, a signed policy, a register entry — not a claim that you ‘do that’. That is exactly what CyberSentien enforces: a control with no evidence reads manual assessment required, never a fabricated pass. How the engine assesses →

Assess once, report everywhere

You do not answer to one framework in isolation. The same body of evidence maps across everything you are accountable to — which is the whole point of assessing once against real evidence and reporting everywhere. Related on this site:

Frequently asked questions

How many controls are in the IEC 62443-3-2-aligned OT risk ZCR 3 — Partition into zones and conduits domain?

There are 7 controls in this domain of IEC 62443-3-2-aligned OT risk. They are all listed above with what each requires.

What evidence satisfies these controls?

Evidence is specific and dated: configuration exports, logs, signed policies, register entries and test results tied to the control, not a written assertion that the control exists. CyberSentien refuses to mark a control compliant without that lineage.

Does CyberSentien assess IEC 62443-3-2-aligned OT risk?

Yes. IEC 62443-3-2-aligned OT risk is one of the frameworks live on the CyberSentien engine, assessed against your real evidence with honest coverage and tamper-evident report lineage.

Every capability referenced on this page is live on the CyberSentien engine — see it on the always-live gated demo. Nothing on this page is legal advice.