NIST SP 800-53 Physical and Environmental Protection controls (2026)

The NIST SP 800-53 Physical and Environmental Protection domain has 58 controls. This page lists every one, in plain language, with what it asks of you and the kind of evidence that actually satisfies it. The US NIST SP 800-53 Rev 5 catalogue of security and privacy controls.

By Aneis Samaan, founder of CyberSentien · Last updated November 2026 · Sourced from the NIST SP 800-53 control set.

What the Physical and Environmental Protection domain covers

These 58 controls are the Physical and Environmental Protection slice of NIST SP 800-53. Read them as the questions an assessor will ask, and the artefacts you will be asked to produce for each. Below every control we keep the language of the source; the value we add is turning each into an evidence question you can answer honestly.

The 58 controls in NIST SP 800-53 Physical and Environmental Protection

ControlWhat it requires
PE-1Policy and Procedures
Develop, document, and disseminate to [organization-defined personnel or roles]: [Selection (one or more): organization-level; mission/business process-level; system-level] physical and environmental protection policy that: Addresses purpose, scope, roles, responsibilities, management commitment, coordination among organizational entities, and compliance; and Is consistent with applicable laws, executive orders, directives, regulations, policies, standards, and guidelines; and Procedures to facilitate the implementation of the physical and environmental protection policy and the associated physical and environmental protection controls; Designate an [organization-defined official] to manage the development, documentation, and dissemination of the physical and environmental protection policy and procedures; and Review and update the current physical and environmental protection: Policy [organization-defined frequency] and following [organization-defined events]; and Procedures [organization-defined frequency] and following [organization-defined events].
PE-2Physical Access Authorizations
Develop, approve, and maintain a list of individuals with authorized access to the facility where the system resides; Issue authorization credentials for facility access; Review the access list detailing authorized facility access by individuals [organization-defined frequency]; and Remove individuals from the facility access list when access is no longer required.
PE-2.1Access by Position or Role
Authorize physical access to the facility where the system resides based on position or role.
PE-2.2Two Forms of Identification
Require two forms of identification from the following forms of identification for visitor access to the facility where the system resides: [organization-defined list of acceptable forms of identification].
PE-2.3Restrict Unescorted Access
Restrict unescorted access to the facility where the system resides to personnel with [Selection (one or more): security clearances for all information contained within the system; formal access authorizations for all information contained within the system; need for access to all information contained within the system; [organization-defined physical access authorizations] ].
PE-3Physical Access Control
Enforce physical access authorizations at [organization-defined entry and exit points] by: Verifying individual access authorizations before granting access to the facility; and Controlling ingress and egress to the facility using [Selection (one or more): [organization-defined systems or devices]; guards]; Maintain physical access audit logs for [organization-defined entry or exit points]; Control access to areas within the facility designated as publicly accessible by implementing the following controls: [organization-defined physical access controls]; Escort visitors and control visitor activity [organization-defined circumstances]; Secure keys, combinations, and other physical access devices; Inventory [organization-defined physical access devices] every [organization-defined frequency]; and Change combinations and keys [organization-defined frequency] and/or when keys are lost, combinations are compromised, or when individuals possessing the keys or combinations are transferred or terminated.
PE-3.1System Access
Enforce physical access authorizations to the system in addition to the physical access controls for the facility at [organization-defined physical spaces].
PE-3.2Facility and Systems
Perform security checks [organization-defined frequency] at the physical perimeter of the facility or system for exfiltration of information or removal of system components.
PE-3.4Lockable Casings
Use lockable physical casings to protect [organization-defined system components] from unauthorized physical access.
PE-3.5Tamper Protection
Employ [organization-defined anti-tamper technologies] to [Selection (one or more): detect; prevent] physical tampering or alteration of [organization-defined hardware components] within the system.
PE-3.6Facility Penetration Testing
Facility Penetration Testing
PE-3.7Physical Barriers
Limit access using physical barriers.
PE-3.8Access Control Vestibules
Employ access control vestibules at [organization-defined locations].
PE-4Access Control for Transmission
Control physical access to [organization-defined system distribution and transmission lines] within organizational facilities using [organization-defined security controls].
PE-5Access Control for Output Devices
Control physical access to output from [organization-defined output devices] to prevent unauthorized individuals from obtaining the output.
PE-5.1Access to Output by Authorized Individuals
Access to Output by Authorized Individuals
PE-5.2Link to Individual Identity
Link individual identity to receipt of output from output devices.
PE-5.3Marking Output Devices
Marking Output Devices
PE-6Monitoring Physical Access
Monitor physical access to the facility where the system resides to detect and respond to physical security incidents; Review physical access logs [organization-defined frequency] and upon occurrence of [organization-defined events]; and Coordinate results of reviews and investigations with the organizational incident response capability.
PE-6.1Intrusion Alarms and Surveillance Equipment
Monitor physical access to the facility where the system resides using physical intrusion alarms and surveillance equipment.
PE-6.2Automated Intrusion Recognition and Responses
Recognize [organization-defined classes or types of intrusions] and initiate [organization-defined response actions] using [organization-defined automated mechanisms].
PE-6.3Video Surveillance
Employ video surveillance of [organization-defined operational areas]; Review video recordings [organization-defined frequency]; and Retain video recordings for [organization-defined time period].
PE-6.4Monitoring Physical Access to Systems
Monitor physical access to the system in addition to the physical access monitoring of the facility at [organization-defined physical spaces].
PE-7Visitor Control
Visitor Control
PE-8Visitor Access Records
Maintain visitor access records to the facility where the system resides for [organization-defined time period]; Review visitor access records [organization-defined frequency]; and Report anomalies in visitor access records to [organization-defined personnel].
PE-8.1Automated Records Maintenance and Review
Maintain and review visitor access records using [organization-defined automated mechanisms].
PE-8.2Physical Access Records
Physical Access Records
PE-8.3Limit Personally Identifiable Information Elements
Limit personally identifiable information contained in visitor access records to the following elements identified in the privacy risk assessment: [organization-defined elements].
PE-9Power Equipment and Cabling
Protect power equipment and power cabling for the system from damage and destruction.
PE-9.1Redundant Cabling
Employ redundant power cabling paths that are physically separated by [organization-defined distance].
PE-9.2Automatic Voltage Controls
Employ automatic voltage controls for [organization-defined critical system components].
PE-10Emergency Shutoff
Provide the capability of shutting off power to [organization-defined system or individual system components] in emergency situations; Place emergency shutoff switches or devices in [organization-defined location] to facilitate access for authorized personnel; and Protect emergency power shutoff capability from unauthorized activation.
PE-10.1Accidental and Unauthorized Activation
Accidental and Unauthorized Activation
PE-11Emergency Power
Provide an uninterruptible power supply to facilitate [Selection: an orderly shutdown of the system; transition of the system to long-term alternate power] in the event of a primary power source loss.
PE-11.1Alternate Power Supply — Minimal Operational Capability
Provide an alternate power supply for the system that is activated [Selection: manually; automatically] and that can maintain minimally required operational capability in the event of an extended loss of the primary power source.
PE-11.2Alternate Power Supply — Self-contained
Provide an alternate power supply for the system that is activated [Selection: manually; automatically] and that is: Self-contained; Not reliant on external power generation; and Capable of maintaining [Selection: minimally required operational capability; full operational capability] in the event of an extended loss of the primary power source.
PE-12Emergency Lighting
Employ and maintain automatic emergency lighting for the system that activates in the event of a power outage or disruption and that covers emergency exits and evacuation routes within the facility.
PE-12.1Essential Mission and Business Functions
Provide emergency lighting for all areas within the facility supporting essential mission and business functions.
PE-13Fire Protection
Employ and maintain fire detection and suppression systems that are supported by an independent energy source.
PE-13.1Detection Systems — Automatic Activation and Notification
Employ fire detection systems that activate automatically and notify [organization-defined personnel or roles] and [organization-defined emergency responders] in the event of a fire.
PE-13.2Suppression Systems — Automatic Activation and Notification
Employ fire suppression systems that activate automatically and notify [organization-defined personnel or roles] and [organization-defined emergency responders]; and Employ an automatic fire suppression capability when the facility is not staffed on a continuous basis.
PE-13.3Automatic Fire Suppression
Automatic Fire Suppression
PE-13.4Inspections
Ensure that the facility undergoes [organization-defined frequency] fire protection inspections by authorized and qualified inspectors and identified deficiencies are resolved within [organization-defined time period].
PE-14Environmental Controls
Maintain [Selection (one or more): temperature; humidity; pressure; radiation; [organization-defined environmental control] ] levels within the facility where the system resides at [organization-defined acceptable levels]; and Monitor environmental control levels [organization-defined frequency].
PE-14.1Automatic Controls
Employ the following automatic environmental controls in the facility to prevent fluctuations potentially harmful to the system: [organization-defined automatic environmental controls].
PE-14.2Monitoring with Alarms and Notifications
Employ environmental control monitoring that provides an alarm or notification of changes potentially harmful to personnel or equipment to [organization-defined personnel or roles].
PE-15Water Damage Protection
Protect the system from damage resulting from water leakage by providing master shutoff or isolation valves that are accessible, working properly, and known to key personnel.
PE-15.1Automation Support
Detect the presence of water near the system and alert [organization-defined personnel or roles] using [organization-defined automated mechanisms].
PE-16Delivery and Removal
Authorize and control [organization-defined types of system components] entering and exiting the facility; and Maintain records of the system components.
PE-17Alternate Work Site
Determine and document the [organization-defined alternate work sites] allowed for use by employees; Employ the following controls at alternate work sites: [organization-defined controls]; Assess the effectiveness of controls at alternate work sites; and Provide a means for employees to communicate with information security and privacy personnel in case of incidents.
PE-18Location of System Components
Position system components within the facility to minimize potential damage from [organization-defined physical and environmental hazards] and to minimize the opportunity for unauthorized access.
PE-18.1Facility Site
Facility Site
PE-19Information Leakage
Protect the system from information leakage due to electromagnetic signals emanations.
PE-19.1National Emissions Policies and Procedures
Protect system components, associated data communications, and networks in accordance with national Emissions Security policies and procedures based on the security category or classification of the information.
PE-20Asset Monitoring and Tracking
Employ [organization-defined asset location technologies] to track and monitor the location and movement of [organization-defined assets] within [organization-defined controlled areas].
PE-21Electromagnetic Pulse Protection
Employ [organization-defined protective measures] against electromagnetic pulse damage for [organization-defined system and system components].
PE-22Component Marking
Mark [organization-defined system hardware components] indicating the impact level or classification level of the information permitted to be processed, stored, or transmitted by the hardware component.
PE-23Facility Location
Plan the location or site of the facility where the system resides considering physical and environmental hazards; and For existing facilities, consider the physical and environmental hazards in the organizational risk management strategy.

The false-green trap in this domain

The failure mode is the same in every framework: a control marked ‘compliant’ with nothing behind it. An assertion is not evidence. For each control above, the honest test is whether you can point to a dated, specific artefact — a configuration export, a log extract, a signed policy, a register entry — not a claim that you ‘do that’. That is exactly what CyberSentien enforces: a control with no evidence reads manual assessment required, never a fabricated pass. How the engine assesses →

Assess once, report everywhere

You do not answer to one framework in isolation. The same body of evidence maps across everything you are accountable to — which is the whole point of assessing once against real evidence and reporting everywhere. Related on this site:

Frequently asked questions

How many controls are in the NIST SP 800-53 Physical and Environmental Protection domain?

There are 58 controls in this domain of NIST SP 800-53. They are all listed above with what each requires.

What evidence satisfies these controls?

Evidence is specific and dated: configuration exports, logs, signed policies, register entries and test results tied to the control, not a written assertion that the control exists. CyberSentien refuses to mark a control compliant without that lineage.

Does CyberSentien assess NIST SP 800-53?

Yes. NIST SP 800-53 is one of the frameworks live on the CyberSentien engine, assessed against your real evidence with honest coverage and tamper-evident report lineage.

Every capability referenced on this page is live on the CyberSentien engine — see it on the always-live gated demo. Nothing on this page is legal advice.