The New Zealand Information Security Manual 10. Infrastructure — 10.1. Cable Management Fundamentals domain has 23 controls. This page lists every one, in plain language, with what it asks of you and the kind of evidence that actually satisfies it. New Zealand Information Security Manual (NZISM) v3.9.
By Aneis Samaan, founder of CyberSentien · Last updated November 2026 · Sourced from the New Zealand Information Security Manual control set.
These 23 controls are the 10. Infrastructure — 10.1. Cable Management Fundamentals slice of New Zealand Information Security Manual. Read them as the questions an assessor will ask, and the artefacts you will be asked to produce for each. Below every control we keep the language of the source; the value we add is turning each into an evidence question you can answer honestly.
| Control | What it requires |
|---|---|
NZISM-10.1.42.C.01 | NZISM 10.1.42.C.01 — Backbone (MUST; Top Secret, Confidential, Secret) Agencies MUST use fibre optic cable for backbone infrastructures and installations. |
NZISM-10.1.42.C.02 | NZISM 10.1.42.C.02 — Backbone (SHOULD; All Classifications) Agencies SHOULD use fibre optic cable for backbone infrastructures and installations. |
NZISM-10.1.43.C.01 | NZISM 10.1.43.C.01 — Use of Fibre Optic Cable (SHOULD; All Classifications) Agencies SHOULD use fibre optic cabling. |
NZISM-10.1.43.C.02 | NZISM 10.1.43.C.02 — Use of Fibre Optic Cable (SHOULD; All Classifications) Agencies SHOULD consult with the GCSB where fibre optic cable incorporating conductive metal strengtheners or sheaths is specified. |
NZISM-10.1.43.C.03 | NZISM 10.1.43.C.03 — Use of Fibre Optic Cable (SHOULD; All Classifications) Agencies SHOULD consult with the GCSB where copper cables are specified. |
NZISM-10.1.43.C.04 | NZISM 10.1.43.C.04 — Use of Fibre Optic Cable (SHOULD NOT; All Classifications) Agencies SHOULD NOT use fibre optic cable incorporating conductive metal strengtheners or sheaths except where essential for cable integrity. |
NZISM-10.1.45.C.01 | NZISM 10.1.45.C.01 — Cable colours (MUST; All Classifications) Agencies MUST comply with the cable and conduit colours specified in the following table. Classification Cable colour Compartmented Information (SCI) Orange/Yellow/Teal or other colour TOP SECRET Red SECRET Blue CONFIDENTIAL Green RESTRICTED and all lower classifications Black |
NZISM-10.1.45.C.02 | NZISM 10.1.45.C.02 — Cable colours (MUST; All Classifications) Additional colours may be used to delineate special networks and compartmented information of the same classification. These networks MUST be labelled and covered in the agency’s SOPs. |
NZISM-10.1.46.C.01 | NZISM 10.1.46.C.01 — Cable colours for foreign systems in New Zealand facilities (MUST; Top Secret) The cable colour to be used for foreign systems MUST be agreed between the host agency, the foreign system owner and the Accreditation Authority. |
NZISM-10.1.46.C.02 | NZISM 10.1.46.C.02 — Cable colours for foreign systems in New Zealand facilities (MUST NOT; Top Secret) Agencies MUST NOT allow cable colours for foreign systems installed in New Zealand facilities to be the same colour as cables used for New Zealand systems. |
NZISM-10.1.46.C.03 | NZISM 10.1.46.C.03 — Cable colours for foreign systems in New Zealand facilities (SHOULD; All Classifications) The cable colour to be used for foreign systems SHOULD be agreed between the host agency, the foreign system owner and the Accreditation Authority. |
NZISM-10.1.46.C.04 | NZISM 10.1.46.C.04 — Cable colours for foreign systems in New Zealand facilities (SHOULD NOT; All Classifications) Agencies SHOULD NOT allow cable colours for foreign systems installed in New Zealand facilities to be the same colour as cables used for New Zealand systems. |
NZISM-10.1.47.C.01 | NZISM 10.1.47.C.01 — Cable groupings (MUST; All Classifications) Agencies MUST contact GCSB for advice when combining the cabling of special networks. |
NZISM-10.1.47.C.02 | NZISM 10.1.47.C.02 — Cable groupings (MUST NOT; All Classifications) Agencies MUST NOT deviate from the approved fibre cable combinations for shared conduits and reticulation systems as indicated below. Group Approved combination 1 UNCLASSIFIED RESTRICTED 2 CONFIDENTIAL SECRET 3 TOP SECRET Other Special Networks |
NZISM-10.1.48.C.01 | NZISM 10.1.48.C.01 — Fibre optic cables sharing a common conduit (MUST; All Classifications) With fibre optic cables the arrangements of fibres within the cable sheath, as illustrated in Figure 3, MUST carry a single classification only. |
NZISM-10.1.48.C.02 | NZISM 10.1.48.C.02 — Fibre optic cables sharing a common conduit (MUST; All Classifications) If a fibre optic cable contains subunits, as shown in Figure 4, each subunit MUST carry only a single classification. |
NZISM-10.1.48.C.03 | NZISM 10.1.48.C.03 — Fibre optic cables sharing a common conduit (MUST NOT; All Classifications) Agencies MUST NOT mix classifications up to RESTRICTED with classifications of CONFIDENTIAL and above in a single cable. |
NZISM-10.1.49.C.01 | NZISM 10.1.49.C.01 — Audio secure areas (MUST; Top Secret) When penetrating an audio secure area for cables, agencies MUST comply with all directions provided by GCSB. |
NZISM-10.1.50.C.01 | NZISM 10.1.50.C.01 — Wall outlet terminations (MUST; All Classifications) Cable groups sharing a wall outlet MUST use different connectors for systems of different classifications. |
NZISM-10.1.50.C.02 | NZISM 10.1.50.C.02 — Wall outlet terminations (MUST; Top Secret) In areas containing outlets for both TOP SECRET systems and systems of other classifications, agencies MUST ensure that the connectors for the TOP SECRET systems are different to those of the other systems. |
NZISM-10.1.50.C.03 | NZISM 10.1.50.C.03 — Wall outlet terminations (MUST; Confidential, Top Secret, Secret) Cable outlets MUST be labelled with the system classification and connector type. |
NZISM-10.1.50.C.04 | NZISM 10.1.50.C.04 — Wall outlet terminations (SHOULD; All Classifications) Cable outlets SHOULD be labelled with the system classification and connector type. |
NZISM-10.1.51.C.01 | NZISM 10.1.51.C.01 — Power Filters (SHOULD; All Classifications) Power filters SHOULD be used to provide a filtered power supply and reduce opportunity for technical attacks. |
The failure mode is the same in every framework: a control marked ‘compliant’ with nothing behind it. An assertion is not evidence. For each control above, the honest test is whether you can point to a dated, specific artefact — a configuration export, a log extract, a signed policy, a register entry — not a claim that you ‘do that’. That is exactly what CyberSentien enforces: a control with no evidence reads manual assessment required, never a fabricated pass. How the engine assesses →
You do not answer to one framework in isolation. The same body of evidence maps across everything you are accountable to — which is the whole point of assessing once against real evidence and reporting everywhere. Related on this site:
There are 23 controls in this domain of New Zealand Information Security Manual. They are all listed above with what each requires.
Evidence is specific and dated: configuration exports, logs, signed policies, register entries and test results tied to the control, not a written assertion that the control exists. CyberSentien refuses to mark a control compliant without that lineage.
Yes. New Zealand Information Security Manual is one of the frameworks live on the CyberSentien engine, assessed against your real evidence with honest coverage and tamper-evident report lineage.
Every capability referenced on this page is live on the CyberSentien engine — see it on the always-live gated demo. Nothing on this page is legal advice.