The New Zealand Information Security Manual 10. Infrastructure — 10.5. Cable Labelling and Registration domain has 12 controls. This page lists every one, in plain language, with what it asks of you and the kind of evidence that actually satisfies it. New Zealand Information Security Manual (NZISM) v3.9.
By Aneis Samaan, founder of CyberSentien · Last updated November 2026 · Sourced from the New Zealand Information Security Manual control set.
These 12 controls are the 10. Infrastructure — 10.5. Cable Labelling and Registration slice of New Zealand Information Security Manual. Read them as the questions an assessor will ask, and the artefacts you will be asked to produce for each. Below every control we keep the language of the source; the value we add is turning each into an evidence question you can answer honestly.
| Control | What it requires |
|---|---|
NZISM-10.5.4.C.01 | NZISM 10.5.4.C.01 — Conduit label specifications (MUST; All Classifications) Agencies MUST comply with the conduit label colours specified in the following table. Classification Cable colour Compartmented Information (SCI) Orange/Yellow/Teal or other colour TOP SECRET Red SECRET Blue CONFIDENTIAL Green RESTRICTED and all lower classifications Black |
NZISM-10.5.5.C.01 | NZISM 10.5.5.C.01 — Installing conduit labelling (SHOULD NOT; All Classifications) Conduit labels installed in public or visitor areas SHOULD NOT be labelled in such a way as to draw attention to or reveal classification of data processed or other agency capability. |
NZISM-10.5.6.C.01 | NZISM 10.5.6.C.01 — Labelling wall outlet boxes (MUST; Secret, Confidential, Top Secret) Wall outlet boxes MUST denote the classification, cable and outlet numbers. |
NZISM-10.5.6.C.02 | NZISM 10.5.6.C.02 — Labelling wall outlet boxes (SHOULD; All Classifications) Wall outlet boxes SHOULD denote the classification, cable and outlet numbers. |
NZISM-10.5.7.C.01 | NZISM 10.5.7.C.01 — Standard operating procedures (SHOULD; All Classifications) The SOPs SHOULD record the site conventions for labelling and registration. |
NZISM-10.5.8.C.01 | NZISM 10.5.8.C.01 — Labelling cables (MUST; Top Secret, Confidential, Secret) Agencies MUST label cables at each end, with sufficient information to enable the physical identification and inspection of the cable. |
NZISM-10.5.8.C.02 | NZISM 10.5.8.C.02 — Labelling cables (SHOULD; All Classifications) Agencies SHOULD label cables at each end, with sufficient information to enable the physical identification and inspection of the cable. |
NZISM-10.5.9.C.01 | NZISM 10.5.9.C.01 — Cable register (MUST; Top Secret, Confidential, Secret) Agencies MUST maintain a register of cables. |
NZISM-10.5.9.C.02 | NZISM 10.5.9.C.02 — Cable register (SHOULD; All Classifications) Agencies SHOULD maintain a register of cables. |
NZISM-10.5.10.C.01 | NZISM 10.5.10.C.01 — Cable register contents (MUST; Secret, Confidential, Top Secret) The cable register MUST record at least the following information: cable identification number; classification; socket number, equipment type, source or destination site/floor plan diagram; and seal numbers if applicable. |
NZISM-10.5.10.C.02 | NZISM 10.5.10.C.02 — Cable register contents (SHOULD; All Classifications) The cable register SHOULD record at least the following information: cable identification number; classification; socket number, equipment type, source or destination site/floor plan diagram; and seal numbers if applicable. |
NZISM-10.5.11.C.01 | NZISM 10.5.11.C.01 — Cable inspections (SHOULD; All Classifications) Agencies SHOULD inspect cables for inconsistencies with the cable register in accordance with the frequency defined in the SSP. |
The failure mode is the same in every framework: a control marked ‘compliant’ with nothing behind it. An assertion is not evidence. For each control above, the honest test is whether you can point to a dated, specific artefact — a configuration export, a log extract, a signed policy, a register entry — not a claim that you ‘do that’. That is exactly what CyberSentien enforces: a control with no evidence reads manual assessment required, never a fabricated pass. How the engine assesses →
You do not answer to one framework in isolation. The same body of evidence maps across everything you are accountable to — which is the whole point of assessing once against real evidence and reporting everywhere. Related on this site:
There are 12 controls in this domain of New Zealand Information Security Manual. They are all listed above with what each requires.
Evidence is specific and dated: configuration exports, logs, signed policies, register entries and test results tied to the control, not a written assertion that the control exists. CyberSentien refuses to mark a control compliant without that lineage.
Yes. New Zealand Information Security Manual is one of the frameworks live on the CyberSentien engine, assessed against your real evidence with honest coverage and tamper-evident report lineage.
Every capability referenced on this page is live on the CyberSentien engine — see it on the always-live gated demo. Nothing on this page is legal advice.