The New Zealand Information Security Manual 10. Infrastructure — 10.6. Patch Panels, Patch Cables and Racks domain has 16 controls. This page lists every one, in plain language, with what it asks of you and the kind of evidence that actually satisfies it. New Zealand Information Security Manual (NZISM) v3.9.
By Aneis Samaan, founder of CyberSentien · Last updated November 2026 · Sourced from the New Zealand Information Security Manual control set.
These 16 controls are the 10. Infrastructure — 10.6. Patch Panels, Patch Cables and Racks slice of New Zealand Information Security Manual. Read them as the questions an assessor will ask, and the artefacts you will be asked to produce for each. Below every control we keep the language of the source; the value we add is turning each into an evidence question you can answer honestly.
| Control | What it requires |
|---|---|
NZISM-10.6.22.C.01 | NZISM 10.6.22.C.01 — Terminations to patch panels (MUST; All Classifications) Agencies MUST ensure that only approved cable groups terminate on a patch panel. |
NZISM-10.6.22.C.02 | NZISM 10.6.22.C.02 — Terminations to patch panels (MUST; All Classifications) RED and BLACK cables must be separated and bundled. |
NZISM-10.6.23.C.01 | NZISM 10.6.23.C.01 — Patch cable and fly lead connectors (MUST; Top Secret, Secret, Confidential) In areas containing cabling for multiple classifications, agencies MUST ensure that the connectors for each classification are distinct and different to those of the other classifications. |
NZISM-10.6.23.C.02 | NZISM 10.6.23.C.02 — Patch cable and fly lead connectors (MUST; Top Secret, Secret, Confidential) In areas containing cabling for multiple classifications, agencies MUST document the selection of connector types for each classification. |
NZISM-10.6.23.C.03 | NZISM 10.6.23.C.03 — Patch cable and fly lead connectors (SHOULD; All Classifications) In areas containing cabling for systems of different classifications, agencies SHOULD ensure that the connectors for each system are different to those of the other systems. |
NZISM-10.6.23.C.04 | NZISM 10.6.23.C.04 — Patch cable and fly lead connectors (SHOULD; All Classifications) In areas containing cabling for systems of different classifications, agencies SHOULD document the selection of connector types. |
NZISM-10.6.24.C.01 | NZISM 10.6.24.C.01 — Physical separation of patch panels (SHOULD; Confidential, Secret, Top Secret) Agencies SHOULD physically separate patch panels of different classifications by installing them in separate cabinets. |
NZISM-10.6.24.C.02 | NZISM 10.6.24.C.02 — Physical separation of patch panels (MUST; Confidential, Secret, Top Secret) Where spatial constraints demand patch panels of different classification are located in the same cabinet, agencies MUST: provide a physical barrier within the cabinet to separate patch panels; ensure that only personnel cleared to the highest classification of the circuits in the panel have access to the cabinet; and obtain approval from the relevant Accreditation Authority prior to installation. |
NZISM-10.6.25.C.01 | NZISM 10.6.25.C.01 — Cabinet Arrangement (SHOULD; Secret, Confidential, Top Secret) Agencies SHOULD arrange the installation of cabinets as follows: RED equipment at the top; BLACK equipment in the centre; Power equipment at the bottom. |
NZISM-10.6.26.C.01 | NZISM 10.6.26.C.01 — Rack Diagrams (SHOULD; All Classifications) Agencies SHOULD record equipment layouts and other relevant information on rack diagrams. |
NZISM-10.6.27.C.01 | NZISM 10.6.27.C.01 — Fly lead installation (SHOULD; Confidential, Top Secret, Secret) Agencies SHOULD ensure that the fibre optic fly leads used to connect wall outlets to IT equipment either: do not exceed 5m in length; or if they exceed 5m in length: are run in the facility’s fixed infrastructure in a protective and easily inspected pathway; are clearly labelled at the equipment end with the wall outlet designator; and are approved by the Accreditation Authority. |
NZISM-10.6.28.C.01 | NZISM 10.6.28.C.01 — Earthing and Bonding (MUST; Confidential, Secret, Top Secret) All earthing points MUST be equipotentially bonded. |
NZISM-10.6.28.C.02 | NZISM 10.6.28.C.02 — Earthing and Bonding (MUST; Confidential, Secret, Top Secret) All conductive elements of a cabinet, rack or case housing any equipment MUST be earth bonded. |
NZISM-10.6.29.C.01 | NZISM 10.6.29.C.01 — Cable Management (MUST; Secret, Confidential, Top Secret) Cabinet rails MUST be installed to: provide adequate room for patch cables and wire managers; provide adequate space for cable management at front, sides, and rear; and arrange switches and patch panels to minimize patching between cabinets & racks. |
NZISM-10.6.30.C.01 | NZISM 10.6.30.C.01 — Labelling Cables (SHOULD; Top Secret, Confidential, Secret) Agencies SHOULD implement the principles and specific cable labelling requirements described above. |
NZISM-10.6.31.C.01 | NZISM 10.6.31.C.01 — Power Cords (SHOULD; Confidential, Secret, Top Secret) Agencies SHOULD follow best practice described above for the installation of power cables. |
The failure mode is the same in every framework: a control marked ‘compliant’ with nothing behind it. An assertion is not evidence. For each control above, the honest test is whether you can point to a dated, specific artefact — a configuration export, a log extract, a signed policy, a register entry — not a claim that you ‘do that’. That is exactly what CyberSentien enforces: a control with no evidence reads manual assessment required, never a fabricated pass. How the engine assesses →
You do not answer to one framework in isolation. The same body of evidence maps across everything you are accountable to — which is the whole point of assessing once against real evidence and reporting everywhere. Related on this site:
There are 16 controls in this domain of New Zealand Information Security Manual. They are all listed above with what each requires.
Evidence is specific and dated: configuration exports, logs, signed policies, register entries and test results tied to the control, not a written assertion that the control exists. CyberSentien refuses to mark a control compliant without that lineage.
Yes. New Zealand Information Security Manual is one of the frameworks live on the CyberSentien engine, assessed against your real evidence with honest coverage and tamper-evident report lineage.
Every capability referenced on this page is live on the CyberSentien engine — see it on the always-live gated demo. Nothing on this page is legal advice.