The New Zealand Information Security Manual 11. Communications Systems and Devices — 11.2. Radio frequency and infrared devices in secure areas domain has 8 controls. This page lists every one, in plain language, with what it asks of you and the kind of evidence that actually satisfies it. New Zealand Information Security Manual (NZISM) v3.9.

By Aneis Samaan, founder of CyberSentien · Last updated November 2026 · Sourced from the New Zealand Information Security Manual control set.

What the 11. Communications Systems and Devices — 11.2. Radio frequency and infrared devices in secure areas domain covers

These 8 controls are the 11. Communications Systems and Devices — 11.2. Radio frequency and infrared devices in secure areas slice of New Zealand Information Security Manual. Read them as the questions an assessor will ask, and the artefacts you will be asked to produce for each. Below every control we keep the language of the source; the value we add is turning each into an evidence question you can answer honestly.

The 8 controls in New Zealand Information Security Manual 11. Communications Systems and Devices — 11.2. Radio frequency and infrared devices in secure areas

ControlWhat it requires
NZISM-11.2.11.C.01NZISM 11.2.11.C.01 — RF devices in secure areas (MUST; Secret, Confidential, Top Secret)
Agencies MUST prevent RF devices from being brought into secure areas unless authorised by the Accreditation Authority.
NZISM-11.2.11.C.02NZISM 11.2.11.C.02 — RF devices in secure areas (SHOULD; All Classifications)
Agencies SHOULD prevent RF devices from being brought into secure areas unless authorised by the Accreditation Authority.
NZISM-11.2.12.C.01NZISM 11.2.12.C.01 — RF controls in secure areas (SHOULD; All Classifications)
Agencies SHOULD limit the effective range of communications outside the agency’s area of control by: minimising the output power level of wireless devices; RF shielding; and Physical layout and separation.
NZISM-11.2.13.C.01NZISM 11.2.13.C.01 — Detecting RF devices in secure areas (SHOULD; Confidential, Secret, Top Secret)
Agencies SHOULD deploy measures to detect and respond to active RF devices within secure areas.
NZISM-11.2.14.C.01NZISM 11.2.14.C.01 — Pointing devices (MUST NOT; Top Secret, Secret, Confidential)
Wireless RF or IR pointing devices MUST NOT be used in secure areas unless approved by the Accreditation Authority and appropriate RF or IR mitigations are implemented.
NZISM-11.2.15.C.01NZISM 11.2.15.C.01 — IR devices in secure areas (MUST NOT; Secret, Confidential)
Agencies using infrared keyboards MUST NOT allow: line of sight and reflected communications travelling into an unsecure area; multiple infrared keyboards at different classifications in the same area; other infrared devices to be brought into line of sight of the keyboard or its receiving device/port; and infrared keyboards to be operated in areas with unprotected windows.
NZISM-11.2.15.C.02NZISM 11.2.15.C.02 — IR devices in secure areas (MUST NOT; Top Secret)
Agencies using infrared keyboards MUST NOT allow: line of sight and reflected communications travelling into an unsecure area; multiple infrared keyboards at different classifications in the same area; other infrared devices within the same area; and infrared keyboards in areas with windows that have not had a permanent method of blocking infrared transmissions applied to them.
NZISM-11.2.15.C.03NZISM 11.2.15.C.03 — IR devices in secure areas (SHOULD; All Classifications)
Agencies using IR devices SHOULD ensure that theIR receiver/port is positioned to prevent line of sight from the secure area boundary.

The false-green trap in this domain

The failure mode is the same in every framework: a control marked ‘compliant’ with nothing behind it. An assertion is not evidence. For each control above, the honest test is whether you can point to a dated, specific artefact — a configuration export, a log extract, a signed policy, a register entry — not a claim that you ‘do that’. That is exactly what CyberSentien enforces: a control with no evidence reads manual assessment required, never a fabricated pass. How the engine assesses →

Assess once, report everywhere

You do not answer to one framework in isolation. The same body of evidence maps across everything you are accountable to — which is the whole point of assessing once against real evidence and reporting everywhere. Related on this site:

Frequently asked questions

How many controls are in the New Zealand Information Security Manual 11. Communications Systems and Devices — 11.2. Radio frequency and infrared devices in secure areas domain?

There are 8 controls in this domain of New Zealand Information Security Manual. They are all listed above with what each requires.

What evidence satisfies these controls?

Evidence is specific and dated: configuration exports, logs, signed policies, register entries and test results tied to the control, not a written assertion that the control exists. CyberSentien refuses to mark a control compliant without that lineage.

Does CyberSentien assess New Zealand Information Security Manual?

Yes. New Zealand Information Security Manual is one of the frameworks live on the CyberSentien engine, assessed against your real evidence with honest coverage and tamper-evident report lineage.

Every capability referenced on this page is live on the CyberSentien engine — see it on the always-live gated demo. Nothing on this page is legal advice.