New Zealand Information Security Manual 17. Cryptography — 17.2. Approved Cryptographic Algorithms controls (2026)

The New Zealand Information Security Manual 17. Cryptography — 17.2. Approved Cryptographic Algorithms domain has 20 controls. This page lists every one, in plain language, with what it asks of you and the kind of evidence that actually satisfies it. New Zealand Information Security Manual (NZISM) v3.9.

By Aneis Samaan, founder of CyberSentien · Last updated November 2026 · Sourced from the New Zealand Information Security Manual control set.

What the 17. Cryptography — 17.2. Approved Cryptographic Algorithms domain covers

These 20 controls are the 17. Cryptography — 17.2. Approved Cryptographic Algorithms slice of New Zealand Information Security Manual. Read them as the questions an assessor will ask, and the artefacts you will be asked to produce for each. Below every control we keep the language of the source; the value we add is turning each into an evidence question you can answer honestly.

The 20 controls in New Zealand Information Security Manual 17. Cryptography — 17.2. Approved Cryptographic Algorithms

ControlWhat it requires
NZISM-17.2.17.C.01NZISM 17.2.17.C.01 — Using Approved Cryptographic Algorithms (MUST; All Classifications)
Agencies MUST ensure that only Approved Cryptographic Algorithms can be used when using an unevaluated product that implements a combination of approved and non-approved Cryptographic Algorithms.
NZISM-17.2.18.C.01NZISM 17.2.18.C.01 — Approved asymmetric/public key algorithms (SHOULD; All Classifications)
Agencies SHOULD use ECDH and ECDSA for all new systems, version upgrades and major system modifications.
NZISM-17.2.19.C.01NZISM 17.2.19.C.01 — Using DH (MUST; All Classifications)
Agencies using DH, for the approved use of agreeing on encryption session keys, MUST use a modulus of at least 3072 bits.
NZISM-17.2.20.C.01NZISM 17.2.20.C.01 — Equipment using DH (MUST; All Classifications)
Devices which are NOT capable of implementing required key lengths MUST be reconfigured with the longest feasible key length as a matter of urgency.
NZISM-17.2.20.C.02NZISM 17.2.20.C.02 — Equipment using DH (MUST; All Classifications)
Devices which are NOT capable of implementing required key lengths MUST be scheduled for replacement as a matter of urgency.
NZISM-17.2.21.C.01NZISM 17.2.21.C.01 — Using DSA (for legacy use only) (MUST; All Classifications)
Agencies using DSA, for the approved use of digital signatures, MUST use a modulus of at least 1024 bits.
NZISM-17.2.22.C.01NZISM 17.2.22.C.01 — Using ECDH (MUST; All Classifications)
Agencies using ECDH, for the approved use of agreeing on encryption session keys, MUST implement the curve P-384 (prime moduli).
NZISM-17.2.22.C.02NZISM 17.2.22.C.02 — Using ECDH (MUST; All Classifications)
All VPN’s using an ECDH key length less than 384 MUST replace all Pre-Shared Keys with keys of at least 384 bits, as soon as possible.
NZISM-17.2.23.C.01NZISM 17.2.23.C.01 — Using ECDSA (MUST; All Classifications)
Agencies using ECDSA, for the approved use of digital signatures, MUST implement the curve P-384 (prime moduli).
NZISM-17.2.24.C.01NZISM 17.2.24.C.01 — Using RSA (MUST; All Classifications)
Agencies using RSA, for the approved use of digital signatures and passing encryption session keys or similar keys, MUST use a modulus of at least 3072 bits.
NZISM-17.2.24.C.02NZISM 17.2.24.C.02 — Using RSA (MUST; All Classifications)
Agencies using RSA, for the approved use of digital signatures and passing encryption session keys or similar keys, MUST ensure that the public keys used for passing encrypted session keys are different to the keys used for digital signatures.
NZISM-17.2.24.C.03NZISM 17.2.24.C.03 — Using RSA (SHOULD; All Classifications)
Agencies using RSA, for the approved use of digital signatures and passing encryption session keys or similar keys, SHOULD use a modulus of at least 4096 bits.
NZISM-17.2.25.C.01NZISM 17.2.25.C.01 — Public key infrastructure using RSA (MUST; All Classifications)
Agencies using RSA keys within internet X.509 Public Key Infrastructure certificates MUST use a modulus of at least 2048 bits.
NZISM-17.2.26.C.01NZISM 17.2.26.C.01 — Approved hashing algorithms (MUST; All Classifications)
Agencies MUST use the SHA-2 family for new systems. Use of SHA-1 is permitted ONLY for legacy systems.
NZISM-17.2.26.C.02NZISM 17.2.26.C.02 — Approved hashing algorithms (MUST; All Classifications)
Agencies MUST use a minimum of SHA-384 when using hashing algorithms to provide integrity protection for information classified as RESTRICTED/SENSITIVE or above.
NZISM-17.2.26.C.03NZISM 17.2.26.C.03 — Approved hashing algorithms (MUST; All Classifications)
In all other cases when information requires integrity protection using hashing algorithms, Agencies MUST use a minimum of SHA-256.
NZISM-17.2.27.C.01NZISM 17.2.27.C.01 — Salts (MUST; All Classifications)
Memorised secrets such as passwords MUST be stored in a form that is resistant to offline attacks.
NZISM-17.2.27.C.02NZISM 17.2.27.C.02 — Salts (SHOULD; All Classifications)
Memorised secrets such as passwords SHOULD be salted and hashed using a suitable one-way key derivation function. See 17.2.14.
NZISM-17.2.27.C.03NZISM 17.2.27.C.03 — Salts (SHOULD; All Classifications)
The salt SHOULD be at least 32 bits in length, be chosen arbitrarily, and each instance is unique so as to minimise salt value collisions among stored hashes.
NZISM-17.2.28.C.01NZISM 17.2.28.C.01 — Approved symmetric encryption algorithms (SHOULD NOT; All Classifications)
Agencies using approved symmetric encryption algorithms (e.g. AES) SHOULD NOT use Electronic CodeBook (ECB) mode.

The false-green trap in this domain

The failure mode is the same in every framework: a control marked ‘compliant’ with nothing behind it. An assertion is not evidence. For each control above, the honest test is whether you can point to a dated, specific artefact — a configuration export, a log extract, a signed policy, a register entry — not a claim that you ‘do that’. That is exactly what CyberSentien enforces: a control with no evidence reads manual assessment required, never a fabricated pass. How the engine assesses →

Assess once, report everywhere

You do not answer to one framework in isolation. The same body of evidence maps across everything you are accountable to — which is the whole point of assessing once against real evidence and reporting everywhere. Related on this site:

Frequently asked questions

How many controls are in the New Zealand Information Security Manual 17. Cryptography — 17.2. Approved Cryptographic Algorithms domain?

There are 20 controls in this domain of New Zealand Information Security Manual. They are all listed above with what each requires.

What evidence satisfies these controls?

Evidence is specific and dated: configuration exports, logs, signed policies, register entries and test results tied to the control, not a written assertion that the control exists. CyberSentien refuses to mark a control compliant without that lineage.

Does CyberSentien assess New Zealand Information Security Manual?

Yes. New Zealand Information Security Manual is one of the frameworks live on the CyberSentien engine, assessed against your real evidence with honest coverage and tamper-evident report lineage.

Every capability referenced on this page is live on the CyberSentien engine — see it on the always-live gated demo. Nothing on this page is legal advice.