The New Zealand Information Security Manual 19. Gateway security — 19.4. Diodes domain has 5 controls. This page lists every one, in plain language, with what it asks of you and the kind of evidence that actually satisfies it. New Zealand Information Security Manual (NZISM) v3.9.
By Aneis Samaan, founder of CyberSentien · Last updated November 2026 · Sourced from the New Zealand Information Security Manual control set.
These 5 controls are the 19. Gateway security — 19.4. Diodes slice of New Zealand Information Security Manual. Read them as the questions an assessor will ask, and the artefacts you will be asked to produce for each. Below every control we keep the language of the source; the value we add is turning each into an evidence question you can answer honestly.
| Control | What it requires |
|---|---|
NZISM-19.4.4.C.01 | NZISM 19.4.4.C.01 — Diode assurance levels (MUST; All Classifications) Agencies MUST use devices as shown in the following table for controlling the data flow of one-way gateways between networks of different classifications. High network Low network You require RESTRICTED UNCLASSIFIED EAL or PP diode RESTRICTED EAL or PP diode CONFIDENTIAL UNCLASSIFIED high assurance diode RESTRICTED high assurance diode CONFIDENTIAL high assurance diode SECRET UNCLASSIFIED high assurance diode RESTRICTED high assurance diode CONFIDENTIAL high assurance diode SECRET high assurance diode TOP SECRET UNCLASSIFIED high assurance diode RESTRICTED high assurance diode CONFIDENTIAL high assurance diode SECRET high assurance diode TOP SECRET high assurance diode |
NZISM-19.4.5.C.01 | NZISM 19.4.5.C.01 — Diode assurance levels for NZEO networks (MUST; All Classifications) Agencies MUST use a diode of at least an EAL assurance level between an NZEO network and a foreign network in addition to the minimum assurance levels for diodes between networks of different classifications. |
NZISM-19.4.5.C.02 | NZISM 19.4.5.C.02 — Diode assurance levels for NZEO networks (MUST; All Classifications) In all other circumstances the table at 19.4.4.C.01 MUST apply. |
NZISM-19.4.5.C.03 | NZISM 19.4.5.C.03 — Diode assurance levels for NZEO networks (SHOULD; All Classifications) Agencies SHOULD use a diode of at least an EAL assurance level or a Protection Profile between an NZEO network and another New Zealand controlled network within a single security domain. |
NZISM-19.4.6.C.01 | NZISM 19.4.6.C.01 — Volume Checking (SHOULD; All Classifications) Agencies deploying a diode to control data flow within one-way gateways SHOULD monitor the volume of the data being transferred. |
The failure mode is the same in every framework: a control marked ‘compliant’ with nothing behind it. An assertion is not evidence. For each control above, the honest test is whether you can point to a dated, specific artefact — a configuration export, a log extract, a signed policy, a register entry — not a claim that you ‘do that’. That is exactly what CyberSentien enforces: a control with no evidence reads manual assessment required, never a fabricated pass. How the engine assesses →
You do not answer to one framework in isolation. The same body of evidence maps across everything you are accountable to — which is the whole point of assessing once against real evidence and reporting everywhere. Related on this site:
There are 5 controls in this domain of New Zealand Information Security Manual. They are all listed above with what each requires.
Evidence is specific and dated: configuration exports, logs, signed policies, register entries and test results tied to the control, not a written assertion that the control exists. CyberSentien refuses to mark a control compliant without that lineage.
Yes. New Zealand Information Security Manual is one of the frameworks live on the CyberSentien engine, assessed against your real evidence with honest coverage and tamper-evident report lineage.
Every capability referenced on this page is live on the CyberSentien engine — see it on the always-live gated demo. Nothing on this page is legal advice.