The New Zealand Information Security Manual 8. Physical Security — 8.1. Facilities domain has 6 controls. This page lists every one, in plain language, with what it asks of you and the kind of evidence that actually satisfies it. New Zealand Information Security Manual (NZISM) v3.9.
By Aneis Samaan, founder of CyberSentien · Last updated November 2026 · Sourced from the New Zealand Information Security Manual control set.
These 6 controls are the 8. Physical Security — 8.1. Facilities slice of New Zealand Information Security Manual. Read them as the questions an assessor will ask, and the artefacts you will be asked to produce for each. Below every control we keep the language of the source; the value we add is turning each into an evidence question you can answer honestly.
| Control | What it requires |
|---|---|
NZISM-8.1.10.C.01 | NZISM 8.1.10.C.01 — Facility physical security (MUST; All Classifications) Agencies MUST ensure that any facility containing a system or its associated infrastructure, including deployable systems, are certified and accredited in accordance with the PSR. |
NZISM-8.1.11.C.01 | NZISM 8.1.11.C.01 — Preventing observation by unauthorised people (SHOULD; All Classifications) Agencies SHOULD prevent unauthorised people from observing systems, in particular desks, screens and keyboards. |
NZISM-8.1.11.C.02 | NZISM 8.1.11.C.02 — Preventing observation by unauthorised people (SHOULD; All Classifications) Agencies SHOULD position desks, screens and keyboards away from windows and doorways so that they cannot be overseen by unauthorised persons. If required, blinds or drapes SHOULD be fixed to the inside of windows, and doors kept closed to avoid oversight. |
NZISM-8.1.12.C.01 | NZISM 8.1.12.C.01 — Bringing non-agency owned devices into secure areas (MUST NOT; Top Secret) Agencies MUST NOT permit non-agency owned devices to be brought into TOP SECRET areas without prior approval from the Accreditation Authority. |
NZISM-8.1.13.C.01 | NZISM 8.1.13.C.01 — Technical Inspection and surveillance counter-measure testing (MUST; Top Secret, Confidential, Secret) Agencies MUST ensure that technical surveillance counter-measure tests are conducted as a part of the physical security certification. |
NZISM-8.1.13.C.02 | NZISM 8.1.13.C.02 — Technical Inspection and surveillance counter-measure testing (MUST; Confidential, Secret, Top Secret) Agencies MUST determine if further technical surveillance counter-measure testing is required, particularly if visitors or contractors have entered secure areas. |
The failure mode is the same in every framework: a control marked ‘compliant’ with nothing behind it. An assertion is not evidence. For each control above, the honest test is whether you can point to a dated, specific artefact — a configuration export, a log extract, a signed policy, a register entry — not a claim that you ‘do that’. That is exactly what CyberSentien enforces: a control with no evidence reads manual assessment required, never a fabricated pass. How the engine assesses →
You do not answer to one framework in isolation. The same body of evidence maps across everything you are accountable to — which is the whole point of assessing once against real evidence and reporting everywhere. Related on this site:
There are 6 controls in this domain of New Zealand Information Security Manual. They are all listed above with what each requires.
Evidence is specific and dated: configuration exports, logs, signed policies, register entries and test results tied to the control, not a written assertion that the control exists. CyberSentien refuses to mark a control compliant without that lineage.
Yes. New Zealand Information Security Manual is one of the frameworks live on the CyberSentien engine, assessed against your real evidence with honest coverage and tamper-evident report lineage.
Every capability referenced on this page is live on the CyberSentien engine — see it on the always-live gated demo. Nothing on this page is legal advice.