IEC 62443-3-3-aligned OT system security FR 1 — Identification and authentication control (2026)

The IEC 62443-3-3-aligned OT system security FR 1 — Identification and authentication control domain has 13 controls. This page lists every one, in plain language, with what it asks of you and the kind of evidence that actually satisfies it. CyberSentien's OT system security assessment, aligned to IEC 62443-3-3.

By Aneis Samaan, founder of CyberSentien · Last updated November 2026 · Sourced from the IEC 62443-3-3-aligned OT system security control set.

What the FR 1 — Identification and authentication control domain covers

These 13 controls are the FR 1 — Identification and authentication control slice of IEC 62443-3-3-aligned OT system security. Read them as the questions an assessor will ask, and the artefacts you will be asked to produce for each. Below every control we keep the language of the source; the value we add is turning each into an evidence question you can answer honestly.

The 13 controls in IEC 62443-3-3-aligned OT system security FR 1 — Identification and authentication control

ControlWhat it requires
SR 1.1Human user identification and authentication
Every human user of the control system is uniquely identified and authenticated before being granted access, on all interfaces the user can reach.
SR 1.2Software process and device identification and authentication
Software processes and devices are identified and authenticated to the control system before they are allowed to communicate or act.
SR 1.3Account management
Accounts on control system components are created, changed, disabled and removed under an authorised, recorded process, including vendor and default accounts.
SR 1.4Identifier management
Identifiers are issued, tracked and withdrawn so that a person, process or device can be attributed to the actions taken under its identifier.
SR 1.5Authenticator management
Authenticators such as passwords, keys, tokens and certificates are issued, protected, changed and revoked under a defined process, with defaults replaced before commissioning.
SR 1.6Wireless access management
Wireless users, devices and access points are identified, authenticated and authorised before joining the control system, and the wireless estate is inventoried.
SR 1.7Strength of password-based authentication
Password composition, length and lifetime are enforced in proportion to the security level the zone requires, allowing for devices that cannot enforce them.
SR 1.8Public key infrastructure certificates
Where public key certificates are used, they are issued, validated, distributed and revoked under a defined certificate management procedure, and a certificate inventory records their expiry.
SR 1.9Strength of public key authentication
Public key authentication validates the certificate chain, its status and the binding to the identity, and protects the associated private key.
SR 1.10Authenticator feedback
Authentication feedback on the human-machine interface does not disclose information that would help an attacker guess or reuse an authenticator.
SR 1.11Unsuccessful login attempts
Repeated failed authentication attempts are limited and acted on in a way that cannot itself deny service to an operator during an upset condition.
SR 1.12System use notification
A system use notification is displayed before authentication where the interface and the operating context allow it.
SR 1.13Access via untrusted networks
Access from untrusted networks is explicitly authorised, monitored, and able to be terminated, and is denied by default where no such authorisation exists.

The false-green trap in this domain

The failure mode is the same in every framework: a control marked ‘compliant’ with nothing behind it. An assertion is not evidence. For each control above, the honest test is whether you can point to a dated, specific artefact — a configuration export, a log extract, a signed policy, a register entry — not a claim that you ‘do that’. That is exactly what CyberSentien enforces: a control with no evidence reads manual assessment required, never a fabricated pass. How the engine assesses →

Assess once, report everywhere

You do not answer to one framework in isolation. The same body of evidence maps across everything you are accountable to — which is the whole point of assessing once against real evidence and reporting everywhere. Related on this site:

Frequently asked questions

How many controls are in the IEC 62443-3-3-aligned OT system security FR 1 — Identification and authentication control domain?

There are 13 controls in this domain of IEC 62443-3-3-aligned OT system security. They are all listed above with what each requires.

What evidence satisfies these controls?

Evidence is specific and dated: configuration exports, logs, signed policies, register entries and test results tied to the control, not a written assertion that the control exists. CyberSentien refuses to mark a control compliant without that lineage.

Does CyberSentien assess IEC 62443-3-3-aligned OT system security?

Yes. IEC 62443-3-3-aligned OT system security is one of the frameworks live on the CyberSentien engine, assessed against your real evidence with honest coverage and tamper-evident report lineage.

Every capability referenced on this page is live on the CyberSentien engine — see it on the always-live gated demo. Nothing on this page is legal advice.