The IEC 62443-3-3-aligned OT system security FR 3 — System integrity domain has 9 controls. This page lists every one, in plain language, with what it asks of you and the kind of evidence that actually satisfies it. CyberSentien's OT system security assessment, aligned to IEC 62443-3-3.
By Aneis Samaan, founder of CyberSentien · Last updated November 2026 · Sourced from the IEC 62443-3-3-aligned OT system security control set.
These 9 controls are the FR 3 — System integrity slice of IEC 62443-3-3-aligned OT system security. Read them as the questions an assessor will ask, and the artefacts you will be asked to produce for each. Below every control we keep the language of the source; the value we add is turning each into an evidence question you can answer honestly.
| Control | What it requires |
|---|---|
SR 3.1 | Communication integrity The integrity of information in transit across the control system and its conduits is protected and verified. |
SR 3.2 | Malicious code protection Protection against malicious code is deployed on endpoints and at entry points, kept current, and its configuration verified, on components where it can run without affecting the control function. |
SR 3.3 | Security functionality verification The security functions of the control system are verified at commissioning and at defined intervals, and the verification is scheduled so that it does not disturb the process. |
SR 3.4 | Software and information integrity Unauthorised change to software, firmware and configuration information is detected, reported and able to be reversed to a known good state. |
SR 3.5 | Input validation Inputs to the control system, including those over the network and from the operator interface, are validated for syntax and range before they are acted on. |
SR 3.6 | Deterministic output The control system places its outputs in a predetermined safe state when normal operation cannot be maintained, confirmed by testing and recorded in an assessment record. |
SR 3.7 | Error handling Errors are handled so that the control system continues to operate safely and discloses no information that would assist an attacker, confirmed by testing and recorded in an assessment record. |
SR 3.8 | Session integrity Sessions are protected against hijacking, replay and injection, including the in validation of session identifiers on termination. |
SR 3.9 | Protection of audit information Audit records and the audit tools are protected from unauthorised access, modification and deletion, including by privileged users. |
The failure mode is the same in every framework: a control marked ‘compliant’ with nothing behind it. An assertion is not evidence. For each control above, the honest test is whether you can point to a dated, specific artefact — a configuration export, a log extract, a signed policy, a register entry — not a claim that you ‘do that’. That is exactly what CyberSentien enforces: a control with no evidence reads manual assessment required, never a fabricated pass. How the engine assesses →
You do not answer to one framework in isolation. The same body of evidence maps across everything you are accountable to — which is the whole point of assessing once against real evidence and reporting everywhere. Related on this site:
There are 9 controls in this domain of IEC 62443-3-3-aligned OT system security. They are all listed above with what each requires.
Evidence is specific and dated: configuration exports, logs, signed policies, register entries and test results tied to the control, not a written assertion that the control exists. CyberSentien refuses to mark a control compliant without that lineage.
Yes. IEC 62443-3-3-aligned OT system security is one of the frameworks live on the CyberSentien engine, assessed against your real evidence with honest coverage and tamper-evident report lineage.
Every capability referenced on this page is live on the CyberSentien engine — see it on the always-live gated demo. Nothing on this page is legal advice.