IEC 62443-3-3-aligned OT system security FR 2 — Use control (2026)

The IEC 62443-3-3-aligned OT system security FR 2 — Use control domain has 12 controls. This page lists every one, in plain language, with what it asks of you and the kind of evidence that actually satisfies it. CyberSentien's OT system security assessment, aligned to IEC 62443-3-3.

By Aneis Samaan, founder of CyberSentien · Last updated November 2026 · Sourced from the IEC 62443-3-3-aligned OT system security control set.

What the FR 2 — Use control domain covers

These 12 controls are the FR 2 — Use control slice of IEC 62443-3-3-aligned OT system security. Read them as the questions an assessor will ask, and the artefacts you will be asked to produce for each. Below every control we keep the language of the source; the value we add is turning each into an evidence question you can answer honestly.

The 12 controls in IEC 62443-3-3-aligned OT system security FR 2 — Use control

ControlWhat it requires
SR 2.1Authorisation enforcement
Authorisations are enforced for every authenticated user, process and device, so that a permitted identity can perform only the actions its role allows.
SR 2.2Wireless use control
Use of wireless connections is restricted to the actions, protocols and endpoints the zone's design permits.
SR 2.3Use control for portable and mobile devices
Portable and mobile devices, including engineering laptops and removable media, are authorised, controlled and checked before they are connected to the control system.
SR 2.4Mobile code
Mobile code is permitted only where it is authorised, its origin is verified, and its execution is confined to what the control system requires.
SR 2.5Session lock
Interactive sessions are locked after a defined period of inactivity, except where locking would impede an operator's ability to respond to a process condition.
SR 2.6Remote session termination
Remote sessions can be terminated by the control system, automatically after inactivity and manually by an authorised operator.
SR 2.7Concurrent session control
The number of concurrent sessions per interface and per account is limited to what the design requires.
SR 2.8Auditable events
Security-relevant events are defined and generated as audit records, including access control, request errors, control system events, backup and restore, configuration change and audit log events.
SR 2.9Audit storage capacity
Audit storage is sized for the defined retention period and its consumption is monitored so that records are not lost silently.
SR 2.10Response to audit processing failures
A failure of audit processing or a full audit store is alerted and handled without the loss of essential control functions.
SR 2.11Timestamps
Audit records carry timestamps from a controlled and synchronised time source, so that events across components can be correlated.
SR 2.12Non-repudiation
Actions taken by identified users on defined critical functions can be attributed to that user and cannot be plausibly denied.

The false-green trap in this domain

The failure mode is the same in every framework: a control marked ‘compliant’ with nothing behind it. An assertion is not evidence. For each control above, the honest test is whether you can point to a dated, specific artefact — a configuration export, a log extract, a signed policy, a register entry — not a claim that you ‘do that’. That is exactly what CyberSentien enforces: a control with no evidence reads manual assessment required, never a fabricated pass. How the engine assesses →

Assess once, report everywhere

You do not answer to one framework in isolation. The same body of evidence maps across everything you are accountable to — which is the whole point of assessing once against real evidence and reporting everywhere. Related on this site:

Frequently asked questions

How many controls are in the IEC 62443-3-3-aligned OT system security FR 2 — Use control domain?

There are 12 controls in this domain of IEC 62443-3-3-aligned OT system security. They are all listed above with what each requires.

What evidence satisfies these controls?

Evidence is specific and dated: configuration exports, logs, signed policies, register entries and test results tied to the control, not a written assertion that the control exists. CyberSentien refuses to mark a control compliant without that lineage.

Does CyberSentien assess IEC 62443-3-3-aligned OT system security?

Yes. IEC 62443-3-3-aligned OT system security is one of the frameworks live on the CyberSentien engine, assessed against your real evidence with honest coverage and tamper-evident report lineage.

Every capability referenced on this page is live on the CyberSentien engine — see it on the always-live gated demo. Nothing on this page is legal advice.